LabIR® NDT is software that uses advanced infrared functions to inspect materials and search for defects. It is used mainly for applications of active thermography and thermographic (infrared) non-destructive testing (IRNDT). It contains all the basic functions of the LabIR software and also allows the use of some special algorithms to process the thermographic signal, such as Time Derivation of The Signal, Pulse-Phase, quantitative evaluation of results using Contrast to Noise Ratio and more.

Cena: 3000 EUR (2,479.34 EUR bez DPH)

Advanced functions of the LabIR® NDT module

  • TDS (Time Derivation of The Signal): a method based on approximation and on signal derivation
  • Pulse-Phase: a method based on phase signal analysis
  • DTSA (Dynamic Thermographic Signal Analysis): method based on time signal analysis developed at the NTC workplace
  • quantitative evaluation of thermograms and defectograms using the CNR function (Contrast To Noise Ratio)
  • transparency of a thermogram or defectogram and blending with photos
  • transformation and pixel conversion to mm for precise positioning in a thermogram
  • thermographic analysis during cyclic loading (tools for inserting time notes to the measurement process and thermal gradient compensation)

Where to use thermography software LabIR® NDT

Science and research

Mechanical engineering

Power engineering

Testing and defectoscopy

Calculation of CNR (Contrast to Noise Ratio) LabIR® NDT
  • Calculation of CNR (Contrast to Noise Ratio)
Real size of the defect: conversion of pixels to mm LabIR® NTC
  • Real size of the defect: conversion of pixels to mm
TDS: possibility to select the degree of derivation LabIR® NDT
  • TDS: possibility to select the degree of derivation
Line temperature profile analysis LabIR® NDT
  • Line temperature profile analysis
  • Thermographic video records / sequences (.seq, .fff), single thermographic images (.img)
  • Internal file formats:
    • FFF (proprietary format for storing thermographic records for FLIR cameras)
    • AFF (proprietary format for storing thermographic records for cameras Agema)
    • CED (proprietary format for storing thermographic records for cameras Cedip)

LabIR® NDT an effective tool for defectoscopy

LabIR® NDT software is a special tool for thermographic defectoscopy. It offers evaluation by modern IRNDT methods (Pulse-Phase, DTSR, TDS). IRNDT software evaluates defects of various materials and products such as: carbon fiber composites, glass samples, plastic welds, steel components, solar panels, thin films and thin walls, food products. It allows inspection of inaccessible places (e.g. piping thickness reduction or material under a painting.

Our Laboratory of active thermography and IR non-destructive testing will be glad to provide you with further information about the methods and development of new infrared test methods here.

Software applications

Inspection of composites

Inspection of transparent material

Inspection of plastic welds

Inspection of surface cracks

A list of all functions of the LabIR®NDT software

Basic functions
  • all functions of the LabIR FREE module (recording, saving and opening of the thermographic record, marking of areas, analyses, etc.)
  • filters application (reference frame, edge detection)
  • region selection and scale customization for NDT analyses
  • approximation of the time progress of the measured signal
Advanced export options
  • thermograms and defectograms in the form of images and data files
  • Data time progress in regions – temperature at thermograms and analyses outputs (average, max, min)
  • time progress of analysis outputs
  • profiles (signal along a line) of thermograms and analysis outputs
  • phase display
  • and more
Advanced methods of evaluation
  • TDS evaluation (Time Derivation of The Signal)
  • Pulse-Phase evaluation
  • DTSA evaluation (dynamic thermographic signal analysis)
  • quantitative evaluation of thermograms and defectograms using the CNR function(Contrast To Noise Ratio)
  • transparency of a thermogram or defectogram and blending with photos
  • transformation and pixel conversion to mm for precise positioning in a thermogram
  • thermographic analysis at cyclical stress (environment for supplementing time notes to the measurement course and thermal gradient compensation)
Other options
  • on the request, we are able to integrate a synchronization box to start the camera and the flash driver
  • on the request, we are able to add additional features

LabIR® software demand

  • Price: 3000 EUR
  • Availabilit: in stock
  • Payment method: transfer to account
  • After receiving your order, we will contact you.
  • *Compulsory data
Basic info
Billing address
Delivery address
Selected product

Do you need help

Contact us and we will be glad to help you with your options.

+420 377 634 804
We use cookies to ensure operations of this website and better quality of our services. If you continue without changing your settings, we'll assume that you agree to receive all cookies. You can change your cookie settings in your web browser. More information